40kw small diesel engine generator for sale
Basic Info
Model No.: HL40GF
Product Description
Short Description of 40kw small diesel engine generator for sale,with 40kW / 50 kVA prime power,and 44 kW / 55 kVA standby power;Voltage:400 / 230 V or 380 / 220 V optional,Frequency:50 HZ,Speed:1500 / 1800 rpm optional.Diesel Generator Set with YUCHAI engine,and water cooled;Alternator is SHUANHUA,STAMFORD or MARATHON optional;Controller:KOMAP or DEEPSEA optional;We have different type generator,such as open type generator, silent / soundproof / quite type generator,trailer type generator,container type generator,and automobile type generator.Our partners are all famous diesel engine manufacturers such as Perkins,MTU,Volvo,Dongfeng Cummins,Chongqing Cummins,Yuchai of China,Shangchai,Weichai Deutz and so on.We have different brand diesel generator set,such as diesel generator set with Cummins Engine,diesel generator set with PERKINS engine,diesel generator set with YUCHAI engine,diesel generator set with MTU engine,diesel generator set with CHINESE engine;We have different kW generator,20-50 kW generator,80-200 kW generator,200-480 kW generator,500-1000 kW generator,and ≥1000kw generator.We have different kVA generator,20-50kva generator,80-200kva generator,200-480kva generator,500-1000kva generator,≥1000kva generator.
Standby power(50HZ):44KW/55KVA
Prime Power(50HZ):40KW/50KVA
Diesel Generator Set Technical Data |
Standby power(50HZ):44KW/55KVA Prime Power(50HZ):40KW/50KVA |
Voltage regulation: ≥±5% Voltage Regulation,Stead State: ≤±1% Sudden Voltage Warp(100% Sudden Reduce): ≤+25% Sudden voltage Warp(Sudden Increase): ≤-20% Voltage Stable Time(100% Sudden Reduce): ≤6S Voltage Stable Time(Sudden Increase): ≤6S Frequency Regulation,Stead State: ≤5% Frequency Waving: ≤1.5% Sudden Frequency Warp(100%Sudden Reduce): ≤+12% Sudden Frequency Warp(Sudden Increase): ≤-10% Frequency Recovery Time(100%Sudden Reduce): ≤5S Frequency Recovery Time(Sudden Increase): ≤5S |
DIESEL ENGINE | |||
ENGINE SPECIFICATIONS | |||
Engine Model | YC4D60-D21 | ||
Manufacturer | GUANGXI YUCHAI MACHINERY Co.,Ltd | ||
Number of cylinders | 4 | cycle | 4 4-cycle |
Air intake way | Natural | Bore(mm) | 108 |
Stroke (mm) | 115 | Compression ratio | 17.0:1 |
Displacement, total (L) | 4.214 | Engine weight,dry (kg) | 360 |
Engine speed (rpm) | 1500 | Noise dB(A) | ≤98 |
Base Output Power (kW) | 40 | Standby Power (kW) | 44 |
Emission | T2 | Starter Mode | Electric |
Oil Capacity(L) | 11-13 | Oil Consumption g/(Kw.h) | ≤1.5 |
Min. Fuel Consumption g/(Kw.h) | ≤205 | Applicable Altitude (m) | ≤1000 |
ALTERNATOR | ||||
Alternator Model | ① | shanhua HLF-40 Prime power (kW) 40KW | ||
|
| |||
Frequency . Speed .Voltage | 50 HZ .1500 rpm.400 v | |||
Voltage regulation | ±0.5% | Rated power factor | 0.8 | |
Alternators meet the requirement of BS EN 60034 and the relevant section of other international stan-dards such as BS5000, VDE 0530, NEMA MG1-32,IEC34, CSAC22.2-100, As1359, and other stand-ards and certifications can be considered on request.The 2/3 pitch design avoids excessive neutral currents. With the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion.Brushless alternator with brushless pilot exciter for excellent load response.The insulation system is class H, easy parallelling with mains or other generators, standard 2/3 pitch stator windings avoid excessive neutral currents. Backed by worldwide service network.
|
Alternators meet the requirement of BS EN 60034 and the relevant section of other international stan-dards such as BS5000, VDE 0530, NEMA MG1-32,IEC34, CSAC22.2-100, As1359, and other stand-ards and certifications can be considered on request.The 2/3 pitch design avoids excessive neutral currents. With the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion.Brushless alternator with brushless pilot exciter for excellent load response.The insulation system is class H, easy parallelling with mains or other generators, standard 2/3 pitch stator windings avoid excessive neutral currents. Backed by worldwide service network.
Genset Dimensions and Weights | |||
OPEN STYLE | |||
Overall Size L×W×H,mm | 1900 | 800 | 1200 |
Weight(radiator model),net,kg | 720 | ||
SOUNDPROOF STYLE | |||
Overall Size L×W×H,mm | 2800 | 1100 | 1750 |
Weight(radiator model),net,kg | 1400 |
Control System | |||||
Description | |||||
Standard functions | Shutdown | Warning | |||
Engine Control Generator Monitoring Generator Protection Engine Monitoring Clear Text Display
| Loss of Speed Signal Alternator Under / Over Voltage Alternator Under/ Over Frequency Mains Under / Over Voltage Mains Under/ Over Frequency Under / Over Speed Low Oil Pressure High Engine Temperature Phase Sequence Electrical (Option) Earth Fault (Option) | Alternator Under / OverVoltage Alternator Under/ OverFrequency Mains Under / Over Voltage Mains Under/ Over Frequency Under / Over Speed Low Oil Pressure Pre-Alarm High Engine TemperaturePre-Alarm High/Low Battery Voltage Over-current Periodic maintenance |
Product Categories : Different Brand Diesel Generator Set > Diesel Generator Set With YUCHAI Engine